Choosing, Installing and Wiring a Home Thermostat

82

By wilderness

Choosing a Home Thermostat

Choosing a new thermostat for your home may be more difficult than the actual thermostat installation and wiring it, so we'll start there. I needed a heat pump thermostat, but most high end thermostats will work on most heating or cooling systems. Begin by questioning yourself - what do you want the thermostat to control, and how? I wanted a programmable digital thermostat that I could program for different temperatures at different times of day, with each day independent of the others; a 7 day programmable thermostat. I have a heat pump with two stage heating plus emergency heat, so a 3 stage thermostat is necessary. My current thermostat, a talking thermostat from Smartway Solutions, was only a two stage thermostat, so I needed to confirm that the thermostat wiring already available was adequate (it was - the extra wires I needed were there, simply unused). I had seen and liked the Honeywell thermostat with a touchscreen so that was a possibility. I wanted to control my second stage heating dependent on outside temperature (an energy savings for heat pumps) so the thermostat must have an outside temperature sensor available. I also found that some of the better thermostats would automatically switch from heating from cooling - nothing I had seen in years past would do that and I find that I like it. We often get swings in temperature where I live that require twice daily adjustments to go from "heat" to "cool" on my past thermostats.

All of these decisions need to be considered when choosing a new thermostat, plus of course cost. Compromises are often possible - perhaps a 5/2 day thermostat would fit your needs with weekdays programming done as a group and weekends done separately. If the existing thermostat wiring is insufficient it will have to be replaced or worked around, perhaps with a thermostat not quite as capable as you want.

Probably the two biggest concerns are the thermostat wiring and the thermostat voltage. The large majority of modern systems use a 24V system, and thermostats reflect that in that almost all of them work on 24 volts. Line voltage thermostats using 120V or 240V are possible - my ancient radiant ceiling heat system has a 240V thermostat in every room that I kept active but unused as an emergency backup to my heat pump and baseboard heaters are nearly all line voltage (that is, the thermostat operates on the same voltage as the heater). If you are unsure of your thermostat voltage it may be checked with a voltmeter at the thermostat base by pulling the thermostat off of the base and checking between the R and C terminals on the base. These are probably red and black wires, but color codes are not always followed and are not completely standardized. It can also be checked in the furnace or air handler, probably by studying the wiring diagram in the unit. CAUTION! If you are not comfortable doing this, don't! The blower section of your system likely has either 120 volts or 240 volts in it that will be live if you are checking voltages. CAUTION!

Recommendations from my HVAC company for a home thermostat

I had been having some trouble with the talking thermostat and high electric bills so I had a local HVAC service company check my heat pump out. During the process, I asked their opinion on a new thermostat and was told they like the Honeywell VisionPro series, and that it would cost me around $400 to have one installed. I declined, thinking that was far too high for a new thermostat, and began checking. I finally decided on the Honeywell VisionPro TH8321U1006 plus a Honeywell C7089 outdoor sensor to go with it. Before making a final decision yourself I strongly suggest that you check the wiring diagram for your new thermostat and compare it to your existing thermostat. My new Honeywell terminal designations matched my old thermostat markings, but If the terminals and number of wires don't match you will have to do some wire tracing or replacement - see the caution above. The Honeywell I purchased has two sets of terminal markings - one for heat pumps and one for conventional - don't get them mixed up!

Honeywell Thermostat and accessories

Honeywell TH8320U1008 7day 3/h 2/c Vision PRO 8000 Touchscreen Programmable Thermostat
Amazon Price: $132.00
List Price: $366.63
Honeywell C7089U1006 Outdoor Temperature Sensor
Amazon Price: $21.51
List Price: $50.88
Honeywell TB8220U1003 Visionpro 8000 Programmable Thermostat
Amazon Price: $160.98
List Price: $439.29

Honeywell VisionPro 8000

Normal operation
See all 4 photos
Normal operation
Programming mode
Programming mode
Outdoor Temperature
Outdoor Temperature

Thermostat base, mounted and wired

Installing and wiring your new thermostat

First step - turn off the power to your heating system! If you have separate heating and cooling systems, turn off the power to both of them! The thermostat wiring you will be most likely dealing with is only 24 volts - it won't shock you but there is some chance of damaging the system. I repeat - turn off the power!

You are now ready for removal of the old thermostat. Most thermostats simply pull on and off the base; pull the thermostat off, revealing the wiring. Carefully note, on paper, which wire goes to which terminal. Write down the terminal markings and colors. The base may now be removed by removing the wires from the base and then removing the base from the wall.

If new or additional thermostat wiring is needed it is time to install it. My system needed a 9 wire cable to the air handler and a 2 wire thermostat wire to the outside temperature sensor. The 9 wire cable was there, but no 2 wire cable, so I had to add that. As the wire simply poked through a very small hole in the drywall, I needed a larger hole to fish new wire - I installed a low voltage "old work" electrical box. This is little more than a plastic frame that will slide into the sheetrock and fasten there and that has holes for the thermostat screws; it is readily available at such stores as Home Depot and Lowes. My existing wiring went down to the crawl space under the house, and I drilled a new hole in the floor near the existing wire so that the hole would be inside the wall above. A long steel wire was used as a guide; I taped the new thermostat wire to it and pushed it up the hole. A helper above reached into the new low voltage box and guided the steel wire out of the wall, then removed the thermostat wire from it and I pulled the steel wire back into the crawl space. As the outdoor sensor required wire through an exterior wall I drilled that hole while in the crawl space.

If you have pulled additional or replacement wire you will have to hook it up in the furnace or air handler. Each system will be different and have different requirements, but if you are knowledgeable enough it is not difficult. I repeat an above warning, however:CAUTION! If you are not comfortable doing this, don't! The blower section of your system likely has either 120 volts or 240 volts in it that will be live if you are checking voltages. CAUTION! There should also be a wiring diagram in the unit to help, and the instructions that came with the Honeywell VisionPro were excellent is describing what each terminal was intended for. I had little trouble in that respect and perhaps the next section can help.

If no additional wire has been installed (the most common case by far) then you are ready to install the wiring to the thermostat base. Carefully refer to the list of original wire placement and install the wires to the appropriate terminal in the new base. I found terminal designations to be the same on both the old and new bases, but referred to both the old and new instruction sets anyway. All the original wires went to the same place - it was the new ones I had installed that didn't. I have 11 wires to the new base and while it looks frightening and impossible to get right it was very easy. One wire at a time and soon it's done and working.

The new thermostat is now pressed onto the base and programming may begin. Again, I cannot help you here as each thermostat is different. What I can say, though is that the Honeywell programming was simple and easy. There are many settings to be checked by the installer, most of which I left in the default position. Others I have changed since, such as the lighting on the face of the thermostat. Programming by the user was also quite straight forward with no problems. A final comment; I would recommend the Honeywell TH8321U1006 that I purchased to almost anyone. It is extremely versatile and will handle most heating/cooling systems. It has a lot of nifty little options that some others don't, and the cost was reasonable at a little over $100. I had to go online to find it, though - Neither Home Depot nor Lowes carried it. For readers that might be interested in additional energy savings, you might look at this article on renovating a sun room

Congratulations - you have a new energy efficient thermostat that you did yourself!

Additional comments for Heat Pump users

In this section I will address additional concerns for you people with a heat pump, as I have. Heat pumps usually have auxiliary and/or emergency heat strips mounted in the air handler. These strips are not used normally - it is only under very cold or emergency (outdoor unit malfunctioning) conditions that they are turned on as they are quite expensive to run. During the process of my research and installation I found that I have three 5KW heat strips, but only two of them were in use. The third was not hooked up at all. As noted above, my old thermostat was only designed for single stage heating plus emergency and would not control the last heat strip. The new Honeywell will handle two stage heating (and two stage cooling, for that matter) plus emergency heat. It will even switch between heat pump and fossil fuel or other heat sources as needed.

It seemed to me that it would be good to use 1 heat strip as auxiliary heat during cold weather, to assist the outdoor unit as needed, while the other two would be used as emergency heat in the rare case that the outdoor compressor quit entirely. They had been hooked up as 2 strips for both purposes - by using only 1 strip I hope to save on my power bill. In addition, I can use the outdoor sensor with the Honeywell 8000 series thermostat to prevent any heat strip coming on at all when the outdoor temperature is above 40 degrees, meaning that I can turn the heat up more than a degree or two without kicking on the auxiliary heat as normally happens with heat pumps. I can also prevent the compressor from operating when outdoor temperatures are very low - it doesn't accomplish much then anyway except burn power.

Now, I am not a HVAC service man, but I am an electrician, and I can follow diagrams and control structures. Unfortunately, the diagrams in my air handler are virtually unreadable and the manufacturer of my heat pump (Amana, by Goodman) would not talk to me at all as soon as they found out I neither sell nor work on HVAC systems. Nevertheless, I was able to trace wiring until I understood what each thermostat wire was intended to do and re-wire the air handler to use the third heat strip as auxiliary heat. Honeywell tells me that in very cold weather the other two strips, wired as emergency heat, will automatically come on, but I have not been able to find any of their literature that agrees with that (edit - emergency heat only comes on when the emergency heat button is pressed. It will not come on automatically). I may have to turn on emergency heat when it gets down to 0 degrees F, but I am willing to do that - we don't get that cold very often. 

Edit - I have found that with temperatures in the low single digits coupled with a 40 year old home a single 5 KW heat strip will not keep up and the temperature in the home falls to around 65 degrees from the set point of 67 degrees.  This only happened twice this winter in my area and is something I'm willing to live with.  Others in colder climates will probably want 2 heat strips to operate as auxiliary heat.

For those readers that understand electrical controls and power, and obviously those that are already familiar with HVAC controls, this is not an impossible task - it is not even particularly difficult and took me about 10 minutes after I had figured out what to do. For the third time, however, I repeat that there is high voltage where you will be working: if you are not comfortable doing this, don't try it!. Any HVAC service company can do the work. At the same time if you are feeling that a simple thermostat change is beyond your abilities I suggest you check out this hub on new homeowners. While aimed at new homeowners the message is just as applicable to the more experienced handyman doing his own work.

Electrical repair and improvement with Wilderness

Comments

Toronto Home Renovations 7 months ago

Tips you mentioned here will be very useful to me. I am very interested in this matter and I myself do a lot of research as well.

http://www.etpainting.com/whole_house_renovations.

wilderness profile image

wilderness Hub Author 7 months ago

Thermostats have come a long, long way from the days of a simple mercury bulb to turn the system on and off. The control possibilities, particularly for a more complex heating and cooling system, are almost limitless. It will pay large dividends to understand what your heating/cooling system is capable of and buy a thermostat that can use those capabilities to their fullest.

Submit a Comment